Precautions for placing fire-fighting equipment

Precautions for placing fire-fighting equipment

  • Categories:Company News
  • Author:
  • Origin:
  • Time of issue:2021-08-30
  • Views:0

(Summary description)How to place the protective equipment? What are the requirements? In real life, in order to play the role of Wenzhou fire-fighting equipment, the correct placement is very important, so what should we pay attention to when placing fire-fighting equipment?

Precautions for placing fire-fighting equipment

(Summary description)How to place the protective equipment? What are the requirements? In real life, in order to play the role of Wenzhou fire-fighting equipment, the correct placement is very important, so what should we pay attention to when placing fire-fighting equipment?

  • Categories:Company News
  • Author:
  • Origin:
  • Time of issue:2021-08-30
  • Views:0
Information

How to place the protective equipment? What are the requirements? In real life, in order to play the role of Wenzhou fire-fighting equipment, the correct placement is very important, so what should we pay attention to when placing fire-fighting equipment?

1. When pipes pass through partition walls and floor slabs, non-combustible materials should be used to close the gaps around them.

2. No doors, windows, or openings should be opened on the firewall. When they must be opened, they should be equipped with Class A fire doors and windows that can close by themselves.

3. The room partition wall with the average weight of combustible materials stored in the basement exceeds 30kg/m2, its fire resistance rating shall not be less than 2.00h, and the room door shall be a Class A fire door.

4. The horizontal distance between the doors, windows and openings on both sides of the firewall should not be less than 2.00m; when the horizontal distance is less than 2.00m, fixed Class B fire doors and windows should be installed.

5. The partition walls in high-rise buildings should be built to the bottom of the beams and slabs, and no gaps should be left.

6. The equipment room, ventilation and air-conditioning machine room of the automatic fire extinguishing system in high-rise buildings shall be separated from other parts by partition walls with a fire resistance rating of not less than 2.00h, and 1.50h floor slabs and Class A fire doors.

7. The firewall should not be located at the inner corners of high-rise buildings such as U and L shapes. When installed near the corner, the horizontal distance between the doors, windows and openings on both sides of the inner corner should not be less than 4.00m; when the adjacent side is equipped with fixed Class B fire windows, the distance can be unlimited.

Scan the QR code to read on your phone

Related_list

The fire hazards that may exist in the fire-fighting equipment itself
The fire hazards that may exist in the fire-fighting equipment itself
Whether it is a fire-fighting supervisor or a unit's fire-fighting management personnel, they often face inspections of fire-fighting equipment.
See more information
Whether it is a fire-fighting supervisor or a unit's fire-fighting management personnel, they often face inspections of fire-fighting equipment.
What facilities are included in fire fighting equipment
What facilities are included in fire fighting equipment
Fire-fighting equipment is very important fire-fighting equipment, so what are the fire-fighting equipment? It mainly includes fire hydrants, fire pump adapters, etc. Let's take a look together!
See more information
Fire-fighting equipment is very important fire-fighting equipment, so what are the fire-fighting equipment? It mainly includes fire hydrants, fire pump adapters, etc. Let's take a look together!
How to choose fire fighting equipment?
How to choose fire fighting equipment?
Time of issue : 2021-08-30 18:44:00
There are many types of fire-fighting equipment on the market, so do you know how to choose fire-fighting equipment? Let's take a look with the fire-fighting equipment manufacturers!
See more information
There are many types of fire-fighting equipment on the market, so do you know how to choose fire-fighting equipment? Let's take a look with the fire-fighting equipment manufacturers!
Previous page
1
2
4

Contact us

Sales Company:
Sales company:Taizhou Sanjiang Global Trade Co., Ltd 

No.74-3, Qingnian South Road, Taizhou City, Jiangsu Province, China
Tel:
0523-86877168 86351119  Fax:0523-86877168 86877119

Sales Company:
Global Fire Safety Science & Technology Yangzhou Co., Ltd
East end of Industrial Clusters Park, Luduo Town, Yangzhou City, Jiangsu Province, China
Tel:
0514-88892119  Fax:0514-88893119

Global Fire Safety Science & Technology Taizhou Co., Ltd
No.5-13,Xinhua Village,Sixiang Town,Medicine high-tech developmental Zone,Taizhou City, Jiangsu Province, China
Tel:
0523-86518119  Fax:0523-86518119

Global Fire Safety Science & Technology Yangzhou Co., Ltd

TOP

Global Fire Safety Science & Technology Yangzhou Co., Ltd   苏ICP备15058518号-1  www.300.cn